External Interfaces
• For instructions on how to connect to other devices, always refer to the “GP-Pro EX
Device/PLC Connection Manual”.
• Always connect the #5 SG (Signal Ground) of the GP unit to the connected device,
especially if the connected device is also not isolated. Failure to do so may damage
the RS232C/RS422/RS485 circuit.
COM1
Recommended Cable Connector XM2D-0901 <made by OMRON Corp.>
Recommended Jack Screw XM2Z-0073 <made by OMRON Corp.>
Recommended Cable Cover XM2S-0913 <made by OMRON Corp.>
Fitting fastener #4-40 (UNC)
Pin #
RS232C RS422/RS485 (Except AGP-3302B)
Signal Name Meaning Signal Name Meaning
1 CD Carrier Detect RDA Receive Data A(+)
2 RD(RXD) Receive Data RDB Receive Data B(-)
3 SD(TXD) Send Data SDA Send Data A(+)
4 ER(DTR) Data Terminal Ready ERA
Data Terminal Ready
A(+)
5 SG Signal Ground SG Signal Ground
6 DR(DSR) Data Set Ready CSB Clear to Send B(-)
7 RS(RTS) Request to Send SDB Send Data B(-)
8 CS(CTS) Clear to Send CSA Clear to Send A(+)
9CI(RI)/VCC
Called status display/
+5 V ±5 % Output 0.25 A
*1
*1 The RI/VCC selection for Pin #9 is switched via software. The VCC output is not protected against
overcurrent. To prevent damage or unit malfunctions, use only the rated current.
ERB Data Terminal Ready B(-)
Shell FG
Frame Ground
(Common with SG)
FG
Frame Ground
(Common with SG)